Abstract

This paper reports test results and numerical analysis of special-shaped beam-column connections based on a frame-shear wall structure. Four connections of 1/5 scale ratio were tested under constant axial force and reversed lateral load on the top of column. The experiment investigated the effect of steel reinforced concrete (SRC) beam, in-plane and out of-plane reinforced concrete (RC) wall on the connections’ seismic behavior. The failure modes, hysteresis curves, ductility, strength degradation and energy-dissipating capacity of test specimens are reported. The results indicated that test joints were susceptible to suffer more brittle failure caused by formation of plastic hinge on column, which is considered unfavorable compared to conventional joint with regular shape in earthquake resisting. Adding in-plane shear walls to the connection switched column failure to beam failure mode, and significantly improved the connection’s strength, stiffness and ductility. Finite element models were detailed established and validated through experiment data. Influence of parameters including axial load ratio, concrete strength grade, section area and steel ratio of upper column, transverse hoops volumetric, RC wall of two orthogonal directions on connection’s seismic behavior were studied through modeling results.