Abstract

An experimental program is summarized which is aimed at enhancing the knowledge base regarding seismic behavior, analysis and of precast concrete shear walls. The emulation design and jointed construction philosophies are described, and an idealization of the behavior of precast shear walls is presented. A compendium of connection details for precast concrete shear walls, seven for vertical joints and four for horizontal joints, is selected for further study and the selection process is described. The connection details are proportioned for a prototype shear wall that is designed as part of a six-story precast concrete office building. A description of all connection details and test procedure is given. Highlights from the cyclic load tests of the vertical joint specimens are documented, including connection resistance, displacement response, initial stiffness and energy dissipation capacity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.