Abstract
The seepage characteristics of foundations with a downstream crack is analysed using conformal transformation technique. Two cases are investigated: a downstream vertical crack in a finite depth of pervious stratum and a downstream inclined crack of finite depth in a pervious stratum of infinite depth. Experimental verification of the flow lines with an electrolytic tank model shows satisfactory agreement with the theory. It is shown that a downstream foundation crack, irrespective of its length and inclination, has negligible effect on the seepage characteristics when the crack is at a distance equal to or greater than the depth of the pervious stratum from the downstream end of the hydraulic structure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.