Abstract

Compared with traditional frequency modulation methods, if a reasonable control method can be adopted, load-side frequency modulation has the advantage of low cost. Air conditioning is a typical high-power household temperature-controlled load. The huge number and outstanding energy storage characteristics make it an important part of demand response and power system frequency modulation. This paper proposes a clustering and equivalent replacement method for air-conditioning load based on K-Means clustering algorithm. Based on the classification algorithm of air-conditioning load, a control strategy based on K-Means clustering algorithm for air-conditioning load participation in secondary frequency modulation of the system was proposed. Aiming at the phenomenon of “secondary peak load” in the process of load recovery in traditional control strategies, the time-sharing grouped frequency modulation control strategy is proposed. The simulation proves the effectiveness of this control strategy in eliminating the “secondary peak load” phenomenon.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.