Abstract
The secondary cooling of AZ80 during DC casting was investigated by measuring the temperature at a given position during steady state. The experiment was carried out under different parameters including the water flow rate density (Q*) and initial temperature (Ti) of the impingement points. To theorize the heat transfer of the secondary cooling zone in practical DC casting, we designed a series of experimental equipment to simulate the secondary cooling with differing Ti (between 473 and 673 K) and Q* (between 20 and 100 L min−1 m−1) based on the DC casting temperature-measurement experiment above. Detailed analysis was carried out of both the experimental results combined with Q*. The empirical formulae of Rohsenow and Weckman were modified due to the need to divide the secondary cooling zone into an impingement zone and a free-falling zone. Finally, a verification of the model’s accuracy was conducted by comparing the results of the finite volume numerical simulation and the experiment, which revealed that the model exhibited extremely high accuracy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.