Abstract

Screwed connections are commonly used in fabricating built-up cold-formed steel (CFS) members. However, the knowledge and understanding of their behaviour and design are limited. This research study investigated the shear behaviour and capacity of the screwed connections used in built-up CFS members. It included a series of shear tests of screwed connections between two single channel members as used in built-up back-to-back CFS members, failing by tilting and bearing. Tests were conducted at both ambient and elevated temperatures. Using the results from these tests and available literature, this study has shown that the design equations for the tilting and bearing capacity of screwed connections in the current CFS design standards are reliable for the screwed connections in built-up CFS members at ambient temperature. It has then shown that the same design equations can be used to predict the tilting and bearing capacity of these screwed connections at elevated temperatures if they are used in combination with the proposed reduction factor equations for elevated temperature capacities. Details of this research study, its results and findings are presented in this paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.