Abstract

The role of particle size on the reduction of granular activated carbon (GAC) adsorption capacity for trace organic contaminants by dissolved organic matter (DOM) is examined and applied to performance scale-up. The adsorption capacity reduction, termed fouling, must be scalable in order to use bench scale tests, such as the rapid small-scale column test (RSSCT) to predict full-scale breakthrough. Equilibrium adsorption capacity tests with GAC preloaded with DOM and RSSCT breakthrough curves at three different GAC particle sizes indicate that GAC adsorption capacity is dependent on GAC particle size when DOM is present. Thus, the RSSCT cannot be expected to match full-scale results regardless of which RSSCT design approach is used (constant or proportional diffusivity), unless a scaling factor is applied to the results. Proportional diffusivity RSSCT breakthrough curves demonstrate that surface concentration of DOM is not a good measure of fouling. It is hypothesized that pore blockage is the mechanism responsible for the dependence on particle size. As GAC particle size increases, the microporous surface area behind a constricted pore also increases. The result is lower adsorption capacity per mass of adsorbent in the larger GAC particles. A scaling methodology for equilibrium and breakthrough data is presented that accounts for the dependence of NOM preloading effects on GAC particle diameter.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call