Abstract This paper discusses the various approaches of representing saturation in the steady–state, two–axis (direct- and quadrature–axis) frame models of synchronous machines. In particular, the important role of the magnetic coupling between the direct-and quadrature axis (cross-magnetizing phenomenon), which is commonly neglected, is demonstrated. A new model and modified active and reactive power/load angle relationships, in which the effect of the cross-magnetizing phenomenon is included, are presented. Experimental verification of the accuracy of this model and these relationships and the importance of the inclusion of the cross-magnetizing effect in them are also reported in the paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.