Abstract

BackgroundT cell immunity plays a pivotal role in mitigating the severity of coronavirus disease 2019 (COVID-19). Therefore, reliable functional T cell assays are required to evaluate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-specific T cell immunity in specific patient populations. MethodsWe recruited a cohort of 23 healthcare workers who received their bivalent Omicron BA.1 / ancestral mRNA booster vaccination or were infected with the Omicron variant at a median of 144 days and 227 days before blood collection, respectively. In this cohort, we compared the performances of two widely utilized commercial SARS-CoV-2 interferon-gamma release assays (IGRAs), i.e., QuantiFERON SARS-CoV-2 and T-SPOT.COVID, and an in-house designed Omicron enzyme-linked immunospot (ELISpot). ResultsThe QuantiFERON SARS-CoV-2 and T-SPOT.COVID assays detected SARS-CoV-2 spike-specific T cells in 34.8 % and 21.7 % of participants, respectively. Moreover, our in-house designed ELISpot that included Omicron BA.4 and BA.5 full-spike peptides detected T cell responses in 47.8 % of participants and was strongly associated with the T-SPOT.COVID. ConclusionThe evaluation of SARS-CoV-2 T cell immunity using commercially accessible assays may yield disparate outcomes as results from different assays are not directly comparable. A specific Omicron ELISpot should be considered to assess Omicron-specific T cell immunity.