Abstract

A novel methodology is described for the sampling and analysis of diacetyl, 2,3-pentanedione, 2,3-hexanedione, and 2,3-heptanedione. These analytes were collected on o-phenylenediamine-treated silica gel tubes and quantitatively recovered as the corresponding quinoxaline derivatives. After derivatization, the sorbent was desorbed in 3 mL of ethanol solvent and analyzed using gas chromatography/nitrogen-phosphorous detection (GC/NPD). The limits of detection (LOD) achieved for each analyte were determined to be in the range of 5–10 nanograms/sample. Evaluation of the on-tube derivatization procedure indicated that it is unaffected by humidities ranging from 20% to 80% and that the derivatization procedure was quantitative for analyte concentrations ranging from 0.1 μg to approximately 500 μg per sample. Storage stability studies indicated that the derivatives were stable for 30 days when stored at both ambient and refrigerated temperatures. Additional studies showed that the quinoxaline derivatives were quantitatively recovered when sampling up to a total volume of 72 L at a sampling rate of 50 cc/min. This method will be important to evaluate and monitor worker exposures in the food and flavoring industry. Samples can be collected over an 8-hour shift with up to 288 L total volume collected regardless of time, sampling rate, and/or the effects of humidity.

Highlights

  • IntroductionNational Institute for Occupational Safety and Health (NIOSH) was asked to investigate a cluster of past and present employees experiencing severe respiratory symptoms after working in microwave popcorn processing facilities over a period of 3 months to 3 years [2]

  • In August 2000, the National Institute for Occupational Safety and Health (NIOSH) received a request for technical assistance (HETA # 00-0401) in an investigation of severe obstructive lung disease in former workers of a microwave popcorn plant in Missouri [1]

  • A NIOSH medical and environmental survey at the plant in November 2000 demonstrated a strong exposure-response relationship between quantities of estimated cumulative exposure to diacetyl and the frequency of airway obstruction on spirometry tests [1]

Read more

Summary

Introduction

NIOSH was asked to investigate a cluster of past and present employees experiencing severe respiratory symptoms after working in microwave popcorn processing facilities over a period of 3 months to 3 years [2]. NIOSH method 2557, an air sampling method that uses Anasorb Carbon Molecular Sieve (CMS) sorbent tubes, was developed based on an urgent need for a method to collect and quantitate exposures and evaluate subsequent engineering control effectiveness [3]. This method was used extensively in the field for a number of years. A NIOSH laboratory-based study and a chamber study with generated atmospheres established a correction method for previously

Methods
Results
Conclusion
Full Text