Abstract

PurposeTo evaluate the impact on the radiation protection policies of the radiocontaminants in Samarium-153 ethylenediamine tetramethylene phosphonate (153Sm-EDTMP). MethodsThe internal contamination of patients treated with 153Sm-EDMTP for palliation of painful disseminated multiple bone metastases due to long-lived impurities was assessed by direct measurements. These measurements were coupled with dose-rate measurements close to their bodies and spectroscopic analysis of the residual activity in post-treatment radiopharmaceutical vials. ResultsWhole-body counting carried out in six patients showed a 30–81-kBq europium −152 plus europium-154 contamination. The 0.85 mean 152Eu- to -154Eu activity ratio obtained by direct counting was similar to that assessed by analysis of post-treatment residual activities in twelve radiopharmaceutical vials following radiopharmaceutical injection. ConclusionsThe long-lived radiocontaminants in the patient's bodies and the treatment wastes require modifications of the applicable radiation protection policies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.