Abstract
The use of natural gas (NG) as an energy source is increasing. This paper studies the safety-zone layout design of a floating power plant fueled by NG. Hazards from the unwanted release of liquefied NG (LNG) in bunkering or NG in operation always exist, and it is thus important to reduce the associated risk to an acceptable level. One engineering technique used to reduce this risk involves the design of a safety zone to prevent and minimize exposure to unwated release of LNG or NG that may occur during the bunkering process. Industry practices are available for the design of the layout of such safety-zones, but their applicability to floating power plants is uncertain, and a more intuitive approach is required. The objective of this study is to discuss the challenges of establishing safety zones on floating power plants by reviewing and comparing existing industrial practices and to propose a hybrid approach for the design of a safety-zone layout. The applicability of the proposed hybrid approach is discussed with an applied example.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.