Abstract

ObjectivesA hostile proximal neck anatomy is the most common cause of abdominal aorta endovascular aneurysm repair failure leading to a higher risk of device migration, proximal type I endoleak, and subsequent open surgical repair. Endostapling is a technique to attain better fixation of the endograft to the aortic wall, and the only available device in the USA is Aptus Heli-FX EndoAnchor system (Medtronic Vascular, Santa Rosa, CA, USA). Preliminary data have shown efficacy and safety of its use, and the aim of this study is to assess device-related adverse events in real-world clinical use.MethodsWe quarried data from the publicly available Manufacturer and User Facility Device Experience database to identify Aptus Heli-FX EndoAnchor system-related adverse reports in endovascular aneurysm repair since FDA approval till August 31, 2017. An estimate of total devices implanted in the United States was quoted around 7,000 (Medtronic marketing internal data).ResultsOur query identified 229 separate reports, of which there were 85 adverse events (1.2% of the estimated EndoAnchor systems used). The most common adverse events were device dislodgement/fracture (65) and applicator malfunction (20).ConclusionIn early post-FDA approval use in a real-world setting, the EndoAnchor system is associated with a low rate of adverse events. Device dislodgement and embolization remain the most common adverse events. With increasing use of these devices in more difficult anatomy, careful patient selection and careful attention to technique may help to reduce these events even further.

Highlights

  • Endovascular aneurysm repair (EVAR) is the preferred treatment modality for an abdominal aortic aneurysm (AAA)

  • Several anatomic features are considered unfavorable for EVAR, which lead to a higher risk of device migration, proximal type I endoleak, and subsequent or rescue open surgical AAA repair.[4]

  • These group of patients face poor outcomes after endovascular repair due to endoleak or graft migration. These challenges have led to developing new techniques/devices to prevent and treat device migration and proximal type I endoleak in patients with hostile neck anatomy

Read more

Summary

Introduction

Endovascular aneurysm repair (EVAR) is the preferred treatment modality for an abdominal aortic aneurysm (AAA). A significant barrier for EVAR is the presence of hostile proximal aortic neck anatomy.[1,2,3] Several anatomic features are considered unfavorable for EVAR, which lead to a higher risk of device migration, proximal type I endoleak, and subsequent or rescue open surgical AAA repair.[4] these group of patients face poor outcomes after endovascular repair due to endoleak or graft migration These challenges have led to developing new techniques/devices to prevent and treat device migration and proximal type I endoleak in patients with hostile neck anatomy. One such technique is endostapling or endotacking, where screw-like anchors are used to attain better approximation and fixation of the endograft to the aortic wall at the proximal neck.[2,5] Currently, the only device approved for clinical use in the USA is the Aptus Heli-FX EndoAnchor system (Medtronic Vascular, Santa Rosa, CA, USA).

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.