Abstract

Different techniques and tools have been introduced for the analysis of process systems that each has their own capabilities namely HAZOP. HAZOP analysis is a process hazard analysis method that has been widely applied both within and outside the chemical processing industries. One of the process systems which require to be analyzed by these techniques is the sulfur recovery unit (SRU) of the gas processing plants. This paper presents the HAZOP analysis method which is employed to identify all the dangerous deviations, potential hazard, and operational problems possibly existing in the Claus reaction furnace package, blower, and heat exchanger equipments in the SRU. This allows a significant reduction in implementation costs, where the expected saving from risk reduction is high. The efficiency of SRU is strongly associated with the performance of those aforementioned equipments. However, it is important to point out that these equipments are the most important parts of the SRU. Useful recommendation is presented to reduce risk ranking. Finally, Cause and effect diagrams for Claus Burner in Start-up/Heating and Fuel Gas + Sour Gas Modes have been designed.