Abstract
Radiofrequency (RF) catheter ablation of para-Hisian accessory pathways (APs) can be challenging due to proximity to the conduction system. A total of 30 consecutive patients with para-Hisian AP were enrolled for ablation in three centers, 12 (40%) of whom had previously failed attempted ablation from the inferior vena cava (IVC) approach. Ablation was preferentially performed using a superior approach from the superior vena cava (SVC) in all patients. The para-Hisian AP was eliminated from the SVC approach in 28 of 30 (93.3%) patients. In the remaining two patients, additional ablation from IVC was required to successfully eliminate the AP. There were two patients experienced reversible complete atrial-ventricular block and PR prolongation during the first RF application. Long-term freedom from recurrent arrhythmia was achieved in 29 (96.7%) patients over a mean follow-up duration of 15.6 ± 4.6 months. Catheter ablation of para-Hisian AP from above using a direct SVC approach is both safe and effective, and should be considered especially in patients who have failed conventional ablation attempts from IVC approach.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.