Abstract

The technique of Rutherford scattering (RS) has been used (for the first time on a reversed-field pinch) to measure the bulk majority ion temperature on the Madison symmetric torus (MST). RS has been in routine operation on MST since December 1999. The neutral beam source and electrostatic energy analyzers which comprise the RS diagnostic were built by the Budker Institute of Nuclear Physics (Novosibrsk, Russia). The source is described in another paper (Abdrashitov et al., these proceedings) and the analyzers are described. A data analysis routine has been developed which yields accurate fits to the data, and estimates of errors in the fit parameters. Typical results are shown.