Abstract
During a 22-month period, 2.0% cadmium chloride in distilled water was included in our routine patch test series. Twenty-five of 1502 eczema patients showed reactions (1.7%), but none had any relevant history. At serial dilution test only one patient reacted to 1.0% cadmium; all the other dilutions applied gave negative reactions. Analysis by atomic absorption spectrophotometry of the cadmium chloride used for patch testing showed that it contained less than 1 microgram/g of chromium, copper, cobalt and nickel. The conclusion is that no certain case of contact allergy to cadmium chloride has been revealed. An experimental study using the guinea pig maximization test is in progress.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.