ABSTRACT The paper discusses effects of main flux saturation in field–oriented induction machines and proposes improved schemes for rotor flux space vector calculation. Field–oriented control with rotor flux computation out of the measured quantities is elaborated. Two rotor flux computer structures are analyzed. The first one is based on stator voltages and currents as measured variables, while the second scheme carries out calculations on the basis of sensed stator currents and rotor speed (position). The sensitivity of the constant parameter rotor flux computers to saturation degree variation is investigated in detail. Modified structures of the computing schemes are then proposed, which account for change in saturation level in the machine. The modified rotor flux calculators are derived from flux state–space model of a saturated induction machine. Accurate computation of rotor flux space vector is enabled in this way, irrespective of the actual saturation level in the machine. Verification of the dev...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.