Abstract

This article presents the fault detection of broken rotor bar (BRB) faults in squirrel cage induction motors (SCIMs). This work applied two diagnostic methods on stator current signal. It is necessary to verify the machine health to avoid any catastrophic damage. The first method uses the fast Fourier transform (FFT) which is generally called motor current signature analysis (MCSA). We carefully verified the spectral content of the stator current to detect BRB fault. The new harmonics allows us to take a good decision about BRB fault. The second method is based on the discrete wavelet transform (DWT). This technique is widely used in the diagnosis field of rotating machinery. According to DWT method, we used the mean square error (MSE) as a good indicator. An experimental test with different conditions of the induction motor has been performed. The experimental results have been exploited using MCSA and DWT methods to achieve a good decision.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.