Abstract

Dual-broadband rotational coherent anti-Stokes Raman spectroscopy (DB-RCARS) has been investigated for thermometry under high-pressure and high-temperature conditions, in the product gas of fuel-lean hydrocarbon flames up to 1 MPa. Initial calibration measurements made in nitrogen, oxygen, and air, at pressures up to 1.55 MPa and temperatures up to 1800 K, showed good agreement between experimental and theoretical spectra. In the high-pressure flames, high-quality single-shot spectra were recorded in which nitrogen lines dominated, and peaks from CO 2 and O 2 were also visible. A spectral model including the species N 2, CO 2, and O 2, as well as the best available Raman linewidth models for flame thermometry, were used to evaluate the experimental spectra. Experimental problems as well as considerations related to the spectral evaluation are discussed. This work demonstrates the significant potential of DB-RCARS thermometry for applications in high-pressure and high-temperature environments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.