Abstract
Comparisons are made, for the first time, between the combustion characteristics of dichloromethane and xylene in an industrial rotary kiln incinerator. The comparisons are made under different operating conditions, including variable kiln rotation rate and operation both with and without turbulence air. Continuous gas composition and temperature measurements and batch gas composition measurements were obtained from two vertical locations hear the exit region of the rotary kiln. The measurements show that there is significant vertical stratification at the exit of the kiln. Addition of turbulence air enhanced combustion conditions throughout the kiln during xylene processing. During dichloromethane processing, however, the addition of turbulence air had minimal effect and only promoted greater bulk mixing; chlorinated compounds transported from the lower kiln during operation with turbulence air were not efficiently processed in the upper kiln. Evolution of test liquids from the bed was not constant but r...
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have