Abstract
Transrectal ultrasound was used to assess anatomic support of the urethrovesical junction (UVJ) in continent and stress incontinent women. UVJ drop on straining of less than 1 cm as assessed by transrectal ultrasound correlated well with good support to the UVJ. Drop of UVJ of more than 1 cm on straining correlated with poor support to bladder neck and stress urinary incontinence. The transrectal technique is quick and easy to perform and interpret.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.