Motorized spiral enteroscopy (MSE) has recently been introduced for small bowel evaluation. In this systematic review and meta-analysis, we aim to evaluate the safety and efficacy of MSE for evaluation of small bowel diseases. A literature search was performed in Embase, PubMed, Medline databases for studies evaluating MSE between January -2010 and October-2022. The primary outcome of the study was diagnostic yield with MSE. Secondary outcomes included technical success, procedure duration, depth of maximum insertion (DMI), rate of pan-enteroscopy and adverse events. 10 studies with 961 patients [581 (60.5%) males] were included in the analysis. 1068 MSE procedures were performed by antegrade route in 698, retrograde route in 215 and bidirectional in 155 patients. Technical success was achieved in 94.9% (95% CI 92.9% to 96.4%) procedures. The pooled diagnostic yield of MSE was 73.7% (95% CI 70.7% to 76.4%). Pooled rate of pan-enteroscopy by antegrade route was 21.9% (95% CI 18.1% to 26.1%), retrograde route was 6.9% (95% CI 2.4% to 18.3%) and combined route was 61.2% (95% CI 52.4% to 69.3%). Pooled rate of major adverse events was 1.9% (95% CI 1.2% to 3.2%). MSE is a safe and effective tool for evaluating small bowel disorders. High diagnostic yield and low rate of adverse events make it a potential alternative to balloon enteroscopy. However, comparative trials are required in the future.