Abstract

Coil misalignment in inductively coupled power transfer (ICPT) systems will lead to fluctuation of transferred power, and even instability of the ICPT systems. To obtain robust control for ICPT system with coil misalignment, a μ-controller based on structured singular value (SSV) is used to set up a closed-loop system in this paper. A generalized state-space averaging (GSSA) model is established using GSSA method first. Then a standard M-Δ configuration is obtained by a linear fractional transformation of the nominal and uncertainty parts of the GSSA model. Finally, a μ-controller is designed by D-K iteration. Besides, the theoretical results are validated by computer simulations and practical experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.