Abstract

A Radio Frequency (RF) probe has been fully modeled, and radiation pattern and realized gain of this probe at mm-wave frequencies have been extracted. Simulation results prove that the probe radiates with a pattern like a dipole showing a realized gain of around −8 dBi at 60 GHz, which is a huge leakage from a probe. The radiation pattern and the realized gain of the probe at 60 GHz have also been measured, confirming the simulation results. © 2011 Wiley Periodicals, Inc. Int J RF and Microwave CAE, 2011.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.