Abstract
Several methodologies have been developed for the calculation of shut-down dose rates based on the use of the Monte Carlo (MC) technique for particle transport simulations including the rigorous two-step (R2S) approach and its recent R2Smesh extension, the direct one-step (D1S) method which employs one single MC transport simulation both for neutrons and decay gammas, and a rough rule of thumb (RoT) approximation based on neutron flux-to-dose conversion factors. The paper discusses these approaches and their applications to ITER with focus on dose rate estimations for the equatorial Test Blanket and Diagnostic Ports. These applications are complemented by benchmark analyses on shut-down dose rate measurements performed on JET showing the validity of the R2S and D1S approaches.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.