Abstract
<p>Two test series with various UHPC strengthening interventions were conducted in this study to investigate the behaviour of composite reinforced concrete (RC) slabs strengthened with UHPC. The first, RE series is a retrofit interventions, tested UHPC as patch material for repairing deteriorated concrete structures. As for the second, OV series is a UHPC overlay interventions, was used to strengthen soffit of RC slab members. The results showed that, in RE series, UHPC safeguard against diagonal cracking compare to conventional RC slab. The UHPC exhibited excellent energy absorption with extensive deflection hardening and ductility during the post cracking range. In OV series, all slabs showed formation of diagonal shear cracks and sign of debonding modes. The UHPC overlay delayed the development of shear cracking. The ultimate load carrying capacity and tendency of flexural failure increase with the overlay thickness.</p>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.