Abstract

BackgroundDetermination of the blood oxyhemoglobin saturation in the retinal vessels of the eye can be achieved through spectrophotometric retinal oximetry which provides access to the state of oxyhemoglobin saturation in the central nervous system circulation. The purpose of this study was to test the capability of the Oxymap T1 oximeter to detect systemic hypoxemia and the effect of supplemental oxygen on retinal vessel oxyhemoglobin saturation.MethodsOxygen saturation of hemoglobin in retinal arterioles and venules was measured in 11 subjects with severe chronic obstructive pulmonary disease (COPD) on long term oxygen therapy. Measurements were made with and without their daily supplemental oxygen. Eleven healthy age and gender matched subjects were measured during ambient air breathing for comparison of oxyhemoglobin saturation in retinal arterioles and venules. Retinal arteriolar oxyhemoglobin saturation in COPD subjects inspiring ambient air was compared with finger pulse oximetry and blood samples from radial artery.ResultsCOPD subjects had significantly lower oxyhemoglobin saturation during ambient air breathing than healthy controls in both retinal arterioles (87.2%±4.9% vs. 93.4%±4.3%, p = 0.02; n = 11) and venules (45.0%±10.3% vs. 55.2%±5.5%, p = 0.01). Administration of their prescribed supplemental oxygen increased oxyhemoglobin saturation in retinal arterioles (87.2%±4.9% to 89.5%±6.0%, p = 0.02) but not in venules (45.0%±10.3% to 46.7%±12.8%, p = 0.3). Retinal oximetry values were slightly lower than radial artery blood values (mean percentage points difference = -5.0±5.4, 95% CI: -15.68 to 5.67) and finger pulse oximetry values (-3.1±5.5, 95% CI: -14.05 to 7.84).ConclusionsThe noninvasive Oxymap T1 retinal oximetry detects hypoxemia in central nervous system vessels in patients with severe COPD compared with healthy controls. The instrument is sensitive to changes in oxygen breathing but displays slightly lower measures than finger pulse oximetry or radial artery measures. With further technological improvement, retinal oximetry may offer noninvasive “on-line” measurement of oxygen levels in central circulation in general anesthesia and critically ill patients.

Highlights

  • The eye is a window to systemic and central nervous system circulation

  • Retinal arteriolar oxyhemoglobin saturation in chronic obstructive pulmonary disease (COPD) subjects inspiring ambient air was compared with finger pulse oximetry and blood samples from radial artery

  • Retinal oximetry values were slightly lower than radial artery blood values and finger pulse oximetry values (-3.1±5.5, 95% comparison post test. (CI): -14.05 to 7.84)

Read more

Summary

Introduction

Its transparent anatomical structure provides a unique opportunity for direct noninvasive observation of arterial blood oxyhemoglobin saturation of retinal vessels; part of the central nervous system circulation. The retina has two separate vascular systems which differ anatomically and physiologically: the retinal circulation which supplies the inner retina and the choroidal circulation which supplies the avascular outer layers of retina. Both these circulations derive from the ophthalmic artery which is the first branch of the internal carotid artery[1] on its way carrying oxygen rich blood from the aorta to the brain. The purpose of this study was to test the capability of the Oxymap T1 oximeter to detect systemic hypoxemia and the effect of supplemental oxygen on retinal vessel oxyhemoglobin saturation

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.