Abstract

PurposeBased on the assumption that high levels of intraocular pressure (IOP) during femtosecond laser-assisted in situ keratomileusis (FS-LASIK) may compromise the retinal nerve fiber layer (RNFL), newer femtosecond platforms that operate without causing significant IOP elevation have been developed in recent years. However, this assumption has not been adequately tested. The aim of the current study was to evaluate possible changes in RFNL thickness in nonglaucomatous myopic patients undergoing FS-LASIK using the 60 KHz IntraLase® device that significantly elevates the IOP for an appreciable period of time vs an advanced surface ablation technique (laser-assisted subepithelial keratomileusis, LASEK) that does not induce any IOP elevation.MethodsThis was a prospective, observational, controlled cohort study. One randomly selected eye of 114 consecutive eligible patients was analyzed. Inclusion criteria were myopia up to -6.00 diopters and astigmatism up to -2.00 diopters. As clinically indicated, 50 patients underwent LASEK and 64 underwent FS-LASIK. The RNFL thickness was determined with a spectral-domain optical coherence tomography device preoperatively and 3 months postoperatively by the same masked observer.ResultsThere was no significant difference in preoperative refractive error, age, or sex between the groups. Preoperatively, central corneal thickness was significantly lower in the LASEK group (529.1±36.1 vs 562.4±31.6 µm, P=0.001). For the LASEK group, there was no significant difference between preoperative and postoperative RNFL thickness in the studied sectors (superior-temporal, temporal, inferior-temporal, average). For the FS-LASIK group, compared to preoperative RNFL measures, statistically significant thicker postoperative values were found for the average RNFL (mean difference: 0.67 µm, 0.7% increase, P=0.008) and the inferior-temporal sector (mean difference: 0.92 µm, 0.6% increase, P=0.02).ConclusionLASIK with a femtosecond platform that induces high intraoperative IOP did not cause RNFL thinning. The observed differences between preoperative and postoperative values are below the axial resolution limit of optical coherence tomography devices.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.