Abstract

The paper presents the review and evaluation of the containment prestressing system within reinforced concrete structures under seismic loads and severe accidents. Given the complex design of the containment, the detailed finite element model has been developed and used to describe real containment behavior. Containment stress and strain state was calculated by modern LIRA software. The first stage analyzed the results of WWER-1000/320 containment stress and strain state calculation under a combination of loads caused by maximum design basis accident (MDBA) and safe shutdown earthquake (SSE) and defined minimum acceptable tension of tendons. The research determines the minimum acceptable tension of tendons in the containment prestressing system, and evaluates the strength and reliability of containment structures under a combination of loads in normal operation + design-basis accident + maximum design earthquake (NO + DBA + MDE). The verification calculations have been performed using tendon tension of 780 ton-force in the cylindrical part of the containment and 760 ton-force in the containment dome.
 The second stage covered the analysis of severe accident parameters (pressure and temperature) and the results of calculation. Stress and strain state in ZNPP-1 containment has been calculated, parameters (pressure and temperature) under which the containment can loss its protective and isolation functions have been identified, calculation results have been analysed and conclusions of containment structural integrity and ensuring the implementation of the design confining functions have been made. Based on the calculation results, it can be concluded that strength of the containment cylindrical part during a beyond design-basis accident cannot be ensured under parameters t (temperature) = 120°С, p (pressure) = 0.6 MPa.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call