Abstract
This study investigated the effectiveness of a biological aerated filter (BAF) as an additional treatment in drinking water treatment plant systems for simultaneous chemical oxygen demand (COD), ammonium (NH4+–N) and manganese (Mn2+) removal. The experimental design was face centered-central composite design (FC-CCD) with three operational variables: COD load, aeration rate (AR) and hydraulic retention time (HRT). Optimum conditions for maximum COD, NH4+–N and Mn2+ removal were determined through response surface methodology, where COD load was set as the maximum while aeration rate and hydraulic retention time were minimized. The optimum conditions were found to be COD load of 0.90kg/m3, AR of 0.30L/min and HRT of 7.47h with predicted simultaneous COD, NH4+–N and Mn2+ removal as 95.5%, 93.9% and 94.8%, respectively. These optimum conditions were used to estimate investment and operating cost of BAF system for a treatment capacity of 100,000m3/day. The total capital and operating costs were estimated to be US$ 8,110,600 and US$ 0.022 per m3, respectively.
Published Version
Talk to us