Abstract

Resistance spot welding characteristics of martensitic sheet steel (M190) was investigated using a peel test, microhardness test, tensile shear test and fatigue test. Tensile shear test provides better spot weld quality than conventional peel test and hardness is not a good indicator of the susceptibility to interfacial fracture. Unlike DP 600 steel, the maximum load carrying capability is affected by the mode of fracture. At high load low cycle range, weld parameters have a significant difference in the S–N curves. But, almost similar fatigue behaviour of the spot welds is noted at low load high cycle range. However, when applied load was converted to stress intensity factor, the difference in fatigue behaviour between welds and even DP 780 steel diminished. Furthermore, a transition in fracture mode, that is, interfacial and plug and hole type at about 50% of yield load were observed. [* Note: Correction made on 16 Aug 2010 after first publication online on 28 June 2010. The authors' affiliations were corrected. Under Results and Discussion, in reference to the HAZ hazardness in the ‘Micro hardness profile’ section, Figure 2 was changed to Figure 3. In reference to the welding parameters under ‘Tensile properties’ section, note that Figure 4 represents 7/200 and Figure 5 represents 5/300. In reference to the low cycles behaviour of S-N curves in the ‘Fatigue’ section, Figure 5 was changed to Figure 6.]

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call