Abstract
Within the theoretical framework supporting the Model Free Adaptive Control approach, this paper investigates on the presence of possible loss of effectiveness affecting the actuator of a Single-Input Single-Output plant. In particular, stemming from a tracking controller proposed in a seminal paper and the related proofs, an identification algorithm is proposed for the estimation of the loss of effectiveness, with proved bounded estimation error, along with a condition for the detection of actuator faults. A fault-resilient tracking controller is finally proposed, based on the estimated loss of effectiveness, providing asymptotically vanishing tracking error. A comparative analysis by simulation on a benchmark system taken from the pertinent literature is also presented to validate the proposed development.