Joints are the forces cross points of members, and the bearing modes are more complex than other members, especially under earthquake action, so the rationality of joints are directly related to the safe reliability of structure. By the pseudo-static test of 4 concrete-filled square steel tubular column and steel beam joint with outer stiffened ring, this paper discusses the failure characteristics, failure mechanism and seismic behavior of joints under different axial compression ratio. The analysis of the testing results shows: the energy dissipation capacity of joints is much better, the degradation of strength and stiffness are slowly when reached the ultimate strength, and the ductility is also good.