In order to study a novel monitoring method suitable for pressure water conveyance project, the fiber grating pressure sensor was adopted for monitoring the water pressure of in-service glass fiber reinforced plastic mortar pipeline. An emptying valve was used in the prototype test to simulate the leakage process and the dynamic water pressure process was recorded effectively by the fiber grating pressure sensor with high frequency and high precision. According to prototype test results, a fluctuation analytical method was proposed, which uses random average pressure as the equilibrium standard value. Meanwhile, an early warning system against pipe failure was developed based on this method. The system was verified by the simulated leakage tests, and the results show that the system could alarm the leakage of more than 0.25% of pipeline design flow, and the positioning accuracy was 10 m–20 m.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.