Abstract

This study seeks to develop a scientific understanding of the effects of dynamic loading history on the low-yield-strength shear panel damper (LYSPD) mechanical properties and fatigue performance. The LYSPD model is supposed as perfect elastic-plastic without strength deterioration. By adjusting the damper strength with the above supposition in the DYMO software, the serial earthquake response waves of the LYSPD under different soil conditions are obtained firstly. Subsequently, several waves, the most prone to damage at each soil condition, are selected as dynamic loading waves to verify the LYSPD dynamic performances experimentally. The test results suggest that the dynamic loading histories have no influence on the LYSPD strength or the supposed model while they affect the fatigue performance. The applicability and accuracy of three fatigue evaluation methods, cumulative plastic shear strain, cumulative energy absorption and Miner rule, are also compared according to the test results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.