Abstract

Passive energy dissipation control system can effectively control structure response under seismic action. As a form of passive energy dissipation control, yielding steel shear panel dampers can dissipate energy of the ground motion very well with the plastic deformation. By monotonic cyclic loading, hysteretic performance of the 15 mm thick core-board nonstiffener shear panel damper is tested, and the test shows that the damper has a superior hysteretic performance. Using finite element analysis software ABAQUS, and taking height to thickness ratio of the core-board as variable, the qualitative analysis on the damper is carried out, and results show that the critical height to thickness ratio of shear panel damper is between 30 and 35. Three groups of 15 mm thick core-board nonstiffener shear panel dampers are tested by constant amplitude cyclic loading under different amplitudes; the results show that the fatigue performance is fine and the damper is a good energy dissipation device.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.