Abstract
Before beginning construction on any civil structure, it is imperative to conduct a soil investigation to determine the soil’s parameters and to learn about the subsoil’s behavior. A thorough analysis must be performed, taking into account the foundation’s cost-effectiveness and any potential overdesign. In the early stages of a soil investigation, geophysical testing is used to find out about the subsurface. This is because geophysical tests are fast, easy to do, do not cause damage, and are cost-effective. In this study, subsurface profiling is performed using the inverse slope approach after resistivity tests are performed at numerous sites on varying terrain types. We generate a subsurface profile using inverse slope electrical resistivity testing and compare it with bore log data to identify any discrepancies. The results of the inverse slope method and the bore log data are comparable at different depths; further, the range of agreement of both results is determined by Bland–Altman analysis.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.