Abstract

It is important to determine the shear resistance of the cold-formed steel stud composite wall which is a main component of the light-weight steel housing. A finite element model (FEM) was introduced in this paper to simulate the shear resistance of this type of composite walls. The material and geometric nonlinear were considered, and the single side gypsum walls and columns are simulated by shell elements, respectively while the screws and frame are modeled by coupling method. The results obtained from FEM were verified against the others’ experimental results. Parametric study is carried out with materials of wall panel, strength of steel members, stud spacing, wall height, and screw spacing to analyze the shear-carrying capacity of the walls. A simplified formula for shear resistance of the composite wall was proposed based on parametric analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.