Abstract

The framed shear wall structure is a high-rise building structure with a transfer story, which has the poor seismic performance (upper rigid and lower flexible). The frame layer in the earthquake is prone to fail, which may even cause the collapse of building. In this paper, it uses the finite element software SATWE to explore the seismic performance of framed shear wall structure. Then we can draw the following conclusions: When the transfer story is set from the third layer to the ninth layer, the earthquake action of transfer story varies from 437.2kN into 564.9kN and is significantly higher than that of upper and lower layers; All the period of free vibration, angles of drift, bottom shear force, overturning moment of the structure have adverse effects on the structure, which are also detrimental to the structural seismic.