Abstract

In order to study the mechanical behaviors of post-tensioned unbonded prestressed concrete hollowed floors, a 1/4 scale post-tensioned unbonded prestressed reinforced concrete hollow slab-column structure model is used to act uniform distributed load on the floor. The test results showed that the load carrying capacity is enough. The points of maximum displacement are at the centers of slabs. By means of the experimental studies and elastic finite element analysis methods, the results showed that post-tensioned unbonded prestressed concrete hollowed floor presents anisotropy with layout of circular-tubes in one way. In direction parallel to layout of hollowed tubes, the continuity of floor is destruction and bending stiffness of slab is weakened. For studying the deformations of slab, it can still be considered continuous cross-slab in two directions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.