Abstract
In Power cycling test, for low-voltage and low-power modules, it is generally considered that the saturation voltage drop VCE(sat) reaches 105% of the initial value or the thermal resistance Rth reaches 120% of the initial value as the basis for judging the failure of the IGBT module. However, since the high-voltage and high-power IGBT modules are connected in parallel with multiple chips, there are differences in the aging speed of the chips, and the degradation of individual chips has little influence on the parameters of the entire module, so the failure judgment standard may not be applicable. In order to obtain the degradation of the characteristic parameters of the high-voltage and high-power IGBT module in the power cycle test, this paper selects the 6500V/600A IGBT module as the research object, adopts the experimental method of constant junction temperature fluctuation, and tests the module parameters after every cycle 20,000 times until the module fails. Three failure modes were found through the test: GE failure, CE failure, GE and CE failure. And the degradation law of the parameters of the high-voltage and high-power IGBT module during the power cycling test was obtained.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.