Abstract
Under the condition of unbalanced load, the three-phase output voltage of three-level inverter is asymmetric. The traditional double closed-loop PI control has a good control effect on the output voltage waveform when the load is balanced, but in the case of unbalanced load, the output voltage waveform contains a negative sequence component, and the control effect on the negative sequence component is limited. In order to improve the output voltage waveform under unbalanced conditions, the 90° symmetric component method is used to separate the positive and negative sequence components, and then PI control is applied to the positive and negative sequence components separately in the dual synchronous rotating coordinate system. Simulations and experiments have verified the correctness of the control strategy, which has a strong harmonic suppression capability and high output voltage quality under unbalanced load conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.