Abstract

Cogeneration nuclear power plants (NPP) can reduce carbon emissions and improve the economy to deal with climate problems. However, after adding the thermal energy supply system (TESS), the nuclear reactor power control system (NRPCS) is affected by the change in the relationship between energy supply and load. Therefore, the NRPCS of VVER-1000 with TESS (Ts-VVER) is studied. In this paper, first, the simulation model of Ts-VVER is established, with the extraction of steam from the main steam header. Second, dynamic characteristic analysis, coupling characteristic analysis, and energy balance relationship analysis are studied to evaluate the influence of Ts-VVER. Then, the NRPCS modified scheme is designed, and the new nonlinear feedforward gain curve is gotten from the original curve by translation. Finally, the designed NRPCS modified scheme is verified by typical conditions simulation. The modified scheme can offer a reference for the design of the NRPCS of other cogeneration NPPs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.