Abstract
This article discussed exhaust gas temperature and pollutant emissions characteristics of the combustion of rich natural gas-air mixtures in Pd metal based honeycomb monoliths in burner during the period of start-up process. The burner need to be ignited by gas phase combustion with the excessive air coefficient (a) at 1.3. The experimental results in catalytic monolith can be explained from SPFR. In this experiment, exhaust gas temperature and pollutant emissions were measured by thermocouple K of diameter 0.5 and the analyser every 1 minute, respectively. The finding would be applied for industrial catalytic combustion process start-up.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.