Abstract

The corona discharge pulse current has double exponential distribution characteristics. On this basis, the electromagnetic radiation model of corona discharge is established by using the theory of electric dipole. The corona discharge characteristics are analysed and compared with the measured results of 1000kV UHV ac transmission line. The results show that the electromagnetic field strength increases first and then decreases with time, and at the same time, the electromagnetic field strength decreases exponentially with distance. The simulated and predicted corona discharge radiation characteristics have the same variation law as the measured data, which verifies the correctness of the model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.