Abstract
A study of ionizing radiation effects is presented for CMOS active pixel sensors manufactured in a 0.5-μm CMOS (complementary metal oxide semiconductor)by n-well technology. The basic mechanisms that may cause failure are also presented. After exposure in γ-rays, the most sensitive parts to radiation-dark signals and dark signal non-uniformity are discussed, i.e. the physical mechanism of the degradation by irradiation. One can see from the experiment that the mean dark signals are dramatically increased with total dose for both operated and static devices. Static device seems more affected by irradiation than operated device. We find that most part of the total dark signal in a pixel comes from the depletion of the photodiode edge at the surface and the rest part is caused by the leakage of the source region of the reset transistor. Dark signal non-uniformity follows the dark current evolution with total dose. Further study of photodiode and LOCOS (local oxidation of silicon) isolation behaviors under irradiation should be done so as to correctly use this qualification techniques on MOS sensors manufactured in CMOS n-well technology process.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.