Abstract

In order to study cube compressive strength of recycled fine aggregate cement mortar after different temperatures, with the affect parameters between replacement rate of recycled fine aggregate and temperature, 45 standard cube test blocks were designed and produced to carry out compressive strength test. The failure process and failure mode of test blocks were observed. Ultimate compressive strength of cube blocks were measured, the relations between cube compressive strength and the replacement rates of recycled fine aggregate under different temperatures as well as the relations between cube compressive strength and temperatures under different replacement rates were all analyzed, the influence change parameters made on cube compressive strength was discussed. The results showed: the failure process and the failure mode of recycled fine aggregate cement mortar and the failure process and the failure mode of nature is similar; when the temperature reached 400°C, the block has no burst phenomenon, but the colour of block into a dark pink; with the increase of recycled fine aggregate, the mass lose rate of block is increase; effect different temperature make on cube compressive strength of test block is not obvious when temperature keeps same for 3h.