Having suffered from the serious environment for ages leads to a decline in the carrying capacity of the derrick as a result of different types of defects. Aiming at a certain derrick tower, finite element analysis software ANSYS was used to calculate and analyze the mode difference of curvature of derrick before and after the damage based on the theory of damage identification from changes in curvature mode shape. Then the conclusion is confirmed by experiments. It shows that local corrosion and bending will cause the change of first two order curvature mode of derrick, and the more is the local damage, the bigger is the mode difference of curvature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.