Abstract

The wide-field imaging system carried on a high-altitude or near-space vehicle takes high-resolution images of the ground to measure and map targets. With the improvement of imaging resolution and measurement accuracy, the focal length of the wide-field imaging system is getting longer. The requirement for image motion compensation (IMC) accuracy is getting higher, and the influence of optical path coupling is increasing within the process of two-dimensional (2D) IMC. To further improve the IMC accuracy of the wide-field imaging system, an innovative IMC method is first proposed in this paper. The method is based on the 2D motion of the scanning platform and secondary mirror. Secondly, to solve the optical coupling problem in the process of 2D IMC, the coupling phenomenon is analyzed. The coupling relationships between 2D scanning motion, 2D secondary mirror motion and image motion is derived from the compensation process. A complete 2D IMC model is established, and a 2D IMC method, including an optical path decoupling correct regulator (ODCR), is designed. Finally, the method is verified in laboratory and field flight tests. The results show that the proposed method can effectively correct the coupling error of the optical path in the process of IMC and achieve high-resolution 2D IMC. When the scanning speed is 60°/s and the exposure time is 2 ms, the accuracy of the 2D IMC is up to 0.57pixels (RMS) in the pitch direction, and 0.46 pixels (RMS) in the roll direction.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call